BRAND | Stahl |
Product | P/N 130828, Type 8040/1180X-35C06SA45 |
Internal code | ONR4775053 |
Technical specification | CONTROL DEVICE SYSTEM SERIES 8040 I ConSig |
Discover the superior quality and performance of the Stahl P/N 130828, Type 8040/1180X-35C06SA45 with Onrion LLC in United States . Whether you are looking for reliability or efficiency, this product meets all your industrial needs.
The P/N 130828, Type 8040/1180X-35C06SA45 is designed to provide optimal performance and durability in various applications. Known for its high-quality construction and innovative features, it is a preferred choice for professionals.
Key Features of P/N 130828, Type 8040/1180X-35C06SA45 :
At Onrion LLC , we offer the P/N 130828, Type 8040/1180X-35C06SA45 at competitive prices and with the fastest delivery times across United States . Our expert team is ready to assist you with all your inquiries and provide tailored solutions to meet your specific needs.
Why Choose Onrion LLC ?
Get Your Quote Today! Ready to enhance your operations with the P/N 130828, Type 8040/1180X-35C06SA45 ? Contact us now for a personalized quote. Fill out the form below or send us an email with your inquiry. Let us help you make a cost-effective, quality-driven choice for your business.
Important Notice: While we supply Stahl products, Onrion LLC is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
8082 / 1-2-00 normally open contact element screw command row of buttons 8082 explosion protected, Connection: Screw Contacts: 1 NO Contact Material: Silver Nickel For use in: Zones 1 & 2
8102/21-32-C995 Junction Box
8118/122-199 Terminal box Ex e
8146/5052-C796 alarm and fire alarm with mushroom put button
control box Type: 8146/5041 Technical specifications: Gas - Explosion protection: Ex II 2 G Ex de IIC T6 Gb Dust - Explosion protection: Ex II 2 D Ex tb IIIC T80 ° C Db IP66 Test Certificate ATEX: PTB 01 ATEX 1024 Test certificate IECEX: IECEx PTB 06.0090 Material: Polyester resin Dimensions: 112 x 170 x 91 mm IP 66 Ambient temperature: -20 ° C ... + 40 ° C Rated voltage: 230 V / 50 Hz Rated current: 6 A Control voltage: V / Hz Schematic: Without wiring Other Approval: on request 1 ST Pilzschluesseltaster EMERGENCY STOP MS 1 Contact element Oe + S 1 ST protective conductor terminal USLKG 5 1 ST: Lower 8161/5 M20-13-fitting M20x1,5sw
Blanking Plug
(nut M16 brass nickel plated 50pcs Locknut, metric brass, nickel plated Internal thread d: M16 x 1.5 Width across flats [mm]: 19 Packing unit: 50pieces CCT No.: 74153300 IN Net weigth: 0,135 KG)
nut M20x1.5
Blanking Plug
(nut M25 brass nickel plated 50pcs Locknut, metric brass, nickel plated Internal thread d: M25 x 1.5 Width across flats [mm]: 29 Packing unit: 50pieces CCT No.: 74153300 IN Net weigth: 0,348 KG)
(blanking plugs f. cable glands Pg9 /M16.....50pcs CCT No.: 39269097 DE Net weigth: 0,061 KG)
(blanking plugs f. multiple cable glands, d 5,5mm...50pcs CCT No.: 39269097 DE Net weigth: 0,031 KG)
Cable gland with reduction sealing insert explosion-protected
8161/5-M16-9 Cable gland Ex e polyamide, 4-9mm, 50 pcs Cable Glands Series 8161, explosion protected Version: 8161/5 Ex e (black) Thread size: M16 x 1.5 Number of entries: 1 Cable dia. range [mm]: 4 ... 9 For use in: Zones 1 & 2, 21 & 22
(Cable Glandsexplosion-protectedType : 8161/5-M25-17Thread size : M25Thread length : 10 mmMaterial : PolyamideColour : blackClamping range : 7 ... 17 mm2Cable armour : Unarmoured cablesApplication range (Zone) : 1 , 2 , 21 , 22Type of protection (IP) : IP66Gas explosion protection : II 2 G Ex e IIDust explosion protection : II 2 D Ex tD A21Min. ambient temperature : -40 °CMax. ambient temperature : +75 °CCCT No.: 39269097 DENet weigth: 0,020 KG)
(Stopping Plug explosion-protected Type : 8290/3-M25 Material : Polyamide Thread size : M25 Drive : Hexagon socket Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex e IIC Gb Dust explosion protection : II 2 D Ex tb IIIC Db Min. ambient temperature : -60 °C Max. ambient temperature : +80 °C Packaging unit : 100 CCT No.: 85389099 DE Net weigth: 0,700 KG)
(Stopping Plug explosion-protected Type : 8290/3-M16 Material : Polyamide Thread size : M16 Drive : Hexagon socket Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex e IIC Gb Dust explosion protection : II 2 D Ex tb IIIC Db Min. ambient temperature : -60 °C Max. ambient temperature : +80 °C Packaging unit : 100 CCT No.: 85389099 DE Net weigth: 0,300 KG)
8491 / 11-230 horn with horn 230V, AC
8491 / 21-230 Flachhupe 230V, AC
8570/12-306 Plug 2P+PE 16A 200-250V, 60+60Hz, 6h, blue
(Push button explosion-protected Type : 8602A0001-1 Enclosure material : Polyamide Seal : Standard Mounting : with threaded Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex e II Dust explosion protection : II 2 D Ex tD A21 Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Type of protection (IP) : IP66 Packed : Yes)
(Rotary handle, large, raised explosion-protected Type : 8602A0724-1-ss-0 Enclosure material : Polyamide Seal : Silicone Mounting : with threaded Padlockable in : no position Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex e II Dust explosion protection : II 2 D Ex tD A21 Min. ambient temperature : -50 °C Max. ambient temperature : +70 °C Type of protection (IP) : IP66 Packed : Yes)
(Label I O II)
labels buttons series 8003
P/N: 160321, Type: 9170/10-12-21S
Switch amplifier digital input
IS PAC Isolating Repeater Switching Repeater Field Circuit Ex i explosion-protected Type : 9170/10-12-21s Max. Voltage Uo : 10,6 V Max. Current Io : 24 mA Max. Demand Po : 64 mW Min. nominal voltage : 120 V Max. nominal voltage : 230 V Nominal current : 12 mA Number of channels : 1 Output / channel : 1 change over contact LFD relay : Yes Line fault transparency : No Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Dust explosion protection : II (1) D [Ex ia] IIIC For further information, see : www.r-stahl.com Web code 9170A Switching Repeater Series 9170, Field Circuit Ex i, single channel Basic function: binary / digital input Intrinsically safe input: [Ex ia] IIC Power supply: 120 ... 230 V AC Input: acc. to EN 60947-5-6 (NAMUR) Output / channel: 1 change-over contact Connection type: Screw terminals
(Emergency Strip light for fluorescent lamps Type: 6608 / 5.2-9 ...-... 7 Specifications: Gas explosion: II 3 G Ex nAC II T4 dust explosion protection: II 2 DT 80 ° C test certificate: DMT 03 E 093 / ATEX e 094 x Suitable for: fluorescent lamp 2Stift, 2 x 18W reflector embodiment: symmetric wide distribution material: polyester resin surface: No coloring IP 66 ambient temperature: -20 ° C ... 40 ° C voltage: 220 V -10%. .. 254 V + 10%; 50/60 Hz cable entry: 2 x cable entry M25x1,5 1 x sealing plug M25x1,5 without bulb through wiring conductors 6 shutdown when opening the luminaire (mains voltage and battery circuit) with duration test)
Repair kit 2x36W QTP8 Ers.QTIS-B Electronic Ballast + Accessories
Repair kit 2x18W QTP8 QTISElektronisches Ers. Ballast + Accessories
Control Pendant selection STH 6102-009