BRAND | Georgin |
Product | RDN 211 000 |
Description | Intrinsically safe relay |
Internal code | ONR4285713 |
Custom code | 85043180 |
Technical specification | 30166 Isolation amplifier 2 channel, 230VAC 2 inputs (contact or NAMUR). 1 SPDT relay output per channel Supply voltage 230VAC ATEX Classification CE 0081 Ex II (1) G/D SIL 2 classification according to IEC 61508 Connection via pluggable spring terminals ATEX/IECEx information: EC type examination certificate LCIE 02 ATEX 6104X IECEx LCI 09.0013X certificate [Ex ia] IIC (-20 °C < Ta < 60 °C) Group II (surface) - category (1) G/D Installation in safe zone barrier for equipment installed in zone 0.1.2 gas or zone 20,21,22 dust Customs tariff number: 8504 3180 Origin: France, EU ref. RDN211000 Intrinsic Safe Relay Input: 2 x switch or proximity sensor Output: 2 x relay (1 RT) via channel Option: without, clamp terminals Power supply: 230 Vac Rail DIN mounting interface ATEX/IECEx information: EC type examination certificate LCIE 02 ATEX 6104X IECEx LCI 09.0013X certificate [Ex ia] IIC (-20 °C < Ta < 60 °C) Group II (surface) - category (1) G/D Installation in safe zone barrier for equipment installed in zone 0.1.2 gas or zone 20,21,22 dust See leaflet for a safe use |
Discover the superior quality and performance of the Georgin RDN 211 000 with Onrion LLC in United States . Whether you are looking for reliability or efficiency, this product meets all your industrial needs.
The RDN 211 000 is designed to provide optimal performance and durability in various applications. Known for its high-quality construction and innovative features, it is a preferred choice for professionals.
Key Features of RDN 211 000 :
At Onrion LLC , we offer the RDN 211 000 at competitive prices and with the fastest delivery times across United States . Our expert team is ready to assist you with all your inquiries and provide tailored solutions to meet your specific needs.
Why Choose Onrion LLC ?
Get Your Quote Today! Ready to enhance your operations with the RDN 211 000 ? Contact us now for a personalized quote. Fill out the form below or send us an email with your inquiry. Let us help you make a cost-effective, quality-driven choice for your business.
Important Notice: While we supply Georgin products, Onrion LLC is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
Insulator 230V AC, input/output 4-20mA
Zener Barriere
Zener diode
range: 115-210 °C sensing element: 2 m capillary- bulb 9 mm diameter, 120 mm length, copper
Capillary temperature switch F series protection : IP66 / ATEX flame proof housing : Ex-proof in epoxy painted-st.st. screws range : -20 to +45 ºC max. temperature : 55 ºC sensing element : 4m capillary-bulb Ø14x150mmmaterial : 316Ti st. st. capillary protection : st. st. armor switch : 1 tropicalized SPDT adjust. deadband :(low/high of range)4-20ºC/1-7ºC current rating : 10A/240VAC - 0.5A/110VDC cable gland : as option (elect. connect. 3/4"NPTF) features: Ex d st. st. tag plate
Capillary temperature switch F series protection : IP66 / ATEX flame proof housing : Ex-proof in epoxy painted-st.st. screws range : 20 to 95 ºC max. temperature : 105 ºC sensing element : 4m capillary-bulb Ø14x150mm material : 316Ti st. st. capillary protection : st. st. armor switch : 1 tropicalized SPDT adjust. deadband :(low/high of range)5-25ºC/1-8ºC current rating : 10A/240VAC - 0.5A/110VDC cable gland : as option (elect. connect. 3/4"NPTF) features: Ex d st. st. tag plate
Pressure switch F series protection : IP66 / ATEX intrinsic safety housing : mazak, epoxy painted range : 5 to 50 bar max. pressure : 80 bar sensing element : bellows material : 316L st. st.
Pressure switch F series
Pressure switch
Pressure switch F series
(Gauge pressure transmitter... GR/GA series housting: stainless steel / protection: IP65 range : 0...50 bar maxi pressure : 150 bar sensor: ceramic cell on viton gasket process connection : 1/2" BSPM - st.st. 316 L electrical connector : DIN43650 power supply : 10...30Vdc output signal : 4...20 mA max. global error : 0.5% FS --------ATEX information------------ EC type examination certificate LCIE 01 ATEX 6137X Ex ia IIC T6 or T5 Ga (-30 Ta 55 or 70Celsius) Ex ia IIIC T80Celsius or T95Celsius Da (-30 Ta 55 Celsius or 70 Celsius Groupe II - category 1GD - Zones 0-1-2 or 20-21-2: Ex ia I - group I (MInes) -CAtegory Mi Production Notification LCIE 02 ATEX Q 8023 See leaflet for a safe use)
Drucktransmitter
Drucktransmitter
Drucktransmitter
SWITCH PRESSURE
(Pressure switch)
pressure Switch
(Pressure switch P series protection : IP66 housing : mazak, epoxy painted-st.st. screws range : 10 to 90 bar max. pressure : 250 bar sensing element : bellows material : 316L st. st. process connection : 1/2"NPTM switch : 2 simultaneous SPDT, dry contact adjust. deadband current rating : 5A/240VAC - 0.5A/110VDC cable gland : polyamid M20 (Ø7.5-13) features: st. st. tag plate)
material : PBT Goods of French / E.U. origin European Customs Tariff Pressure Switch : 9032 2000
Druckschalter mit Flansch
Pressure indicator
pressure switch
Manometer
Gauge pressure transmitter
Gauge pressure transmitter
Gauge pressure transmitter