BRAND | Mecon |
Product | TL3A0-LQ |
Internal code | ONR4930675 |
Custom code | 90261081 |
Technical specification | Turbo-Lux 3 DN200 2000 GPM KIT Description: Turbo-Lux 3 workings Measurement principle: Diaphragm as differential pressure transmitter with bypass flow meter flow direction: arbitrary, taking into account the direction of the arrow Installation position: any Measurement accuracy Measurement deviation: ±2.0% of the end value of the measurement range (FM) ± 5.0% of measurement value (LPCB) ±2.5% of the final measurement range value (vDS) process conditions Nominal size: 8"/DN 200 (ø 219.1 mm) grooved Pump rated power: 2000 usGpm Inlet and outlet distance:5 x D and 2 x D Display range: 800 — 4000 usGPM 3000 - 15000 lpm Installation length: 200 mm (+0.0 mm/-3.0 mm) operating conditions Medium: water Operating temperature: +4 to +50 °C max. operating pressure: FM 500 psi (34.5 bar) LPCB/ VdS PN 16 (232 psi) Constructive structure Housing tube: painted steel with rolled groove Differential pressure collection tube: brass Floater: stainless steel Bypass valve: stainless steel Filter screen: stainless steel Filter screen: stainless steel Seal: NBR Certificates/Approvals FM LPCB VdS Measurement accuracy certificate (bypass meter): with AL: N ECCN: N PREF-J: ALL |
Discover the superior quality and performance of the Mecon TL3A0-LQ with Onrion LLC in United States . Whether you are looking for reliability or efficiency, this product meets all your industrial needs.
The TL3A0-LQ is designed to provide optimal performance and durability in various applications. Known for its high-quality construction and innovative features, it is a preferred choice for professionals.
Key Features of TL3A0-LQ :
At Onrion LLC , we offer the TL3A0-LQ at competitive prices and with the fastest delivery times across United States . Our expert team is ready to assist you with all your inquiries and provide tailored solutions to meet your specific needs.
Why Choose Onrion LLC ?
Get Your Quote Today! Ready to enhance your operations with the TL3A0-LQ ? Contact us now for a personalized quote. Fill out the form below or send us an email with your inquiry. Let us help you make a cost-effective, quality-driven choice for your business.
Important Notice: While we supply Mecon products, Onrion LLC is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
Orifice for installation between flanges: DN 150 (Qv: 1.2 to 6.0 m³ / min.) Zentrierbausatz metering station for installation between flanges: no In addition to current meter FO Turbo-Lux 2: With bypass meter Turbo-Lux 2 for Orifice for installation between flanges Spare cap: without cap Calibration certificate (only for bypass meter): without calibration certificate
Zentrierbausatz metering station for installation between flanges: no In addition to current meter FO Turbo-Lux 2: With bypass meter Turbo-Lux 2 for Orifice for installation between flanges Spare cap: without cap Calibration certificate (only for bypass meter): without calibration certificate
flowmeter
flowmeter
FLOW TRE EASTERN CONNECTION
FLOW SWITCH
Turbo-Lux 3
7ME5820-2DV20-0AA1 - obsolete, alternative is 7ME5820-2DV20-0BB1
VARIABLE AREA FLOWMETERS
Turbo-Lux® 3 Orifice flow meters
Turbo-Lux® 3 Orifice flow meters
Stainless steel baffle plate
Electromagnetic flow Sensor mag-flux A
Transmitter mag-flux M1
Electromagnetic flow sensor
flowmeter
Turbo-Lux 2 centering kit DN 150 PN 16
flow switch
flow switch
cylinder air flow switch
TUBUX M30 / 7ME5812-2FH14-0DD0/Y01
GLASS TUBE FLOAT FLOW